Tuesday, May 22, 2012

Problem Description:


===================

While cloning the R12 instance apps Tier the following Error occurs at 3% after running adcfgclone.pl.



Error:


======


ouicli.pl INSTE8_APPLY -1



The following report lists errors AutoConfig encountered during each


phase of its execution. Errors are grouped by directory and phase.


The report format is:





[APPLY PHASE]


AutoConfig could not successfully execute the following scripts:


Directory: /testapps/apps/tech_st/10.1.3/perl/bin/perl -I /testapps/apps/tech_st/10.1.3/perl/lib/5.8.3 -I /testapps/apps/tech_st/10.1.3/perl/lib/site_per


l/5.8.3 -I /testapps/apps/apps_st/appl/au/12.0.0/perl -I /testapps/apps/tech_st/10.1.3/Apache/Apache/mod_perl/lib/site_perl/5.8.3/aix-thread-multi /testapps/


apps/tech_st/10.1.2/appsutil/clone


ouicli.pl INSTE8_APPLY -1


AutoConfig is exiting with status 1



RC-50013: Fatal: Instantiate driver did not complete successfully.


/testapps/apps/tech_st/10.1.2/appsutil/driver/regclone.drv


Cause:


=======

During the Configuration of the APPS-Tier Technology Stack the opmn process tries to stop the Services. As opmn is not used in this case for the 10.1.2 ORACLE_HOME it should not have been started. The OUI (Oracle Universal Installer) is waiting for a failure or error of the opmn, which is not happening. As a result the OUI Cloning process is failing with a timeout, without touching the Technology Stack.


This issue is reported in unpublished Bug 5697740 - 'OPMN START FAILED DURING OH10.1.2 CLONING.'


Solution:

1. Open a dupicate session for apps tier


ps -ef|grep opmn

If there is any opmn the follow the below procedure


appltest 10879108 1 0 10:33:14 pts/1 0:00 /testapps/apps/tech_st/10.1.2/opmn/bin/opmn -a -q ping


appltest 30867490 40960050 0 10:40:40 - 0:00 /testapps/apps/tech_st/10.1.2/opmn/bin/opmn -a -q pingwait


appltest 40632488 17760288 0 10:40:50 pts/0 0:00 grep opmn


appltest 40960050 41812148 0 01:51:35 - 0:00 /bin/sh /testapps/apps/tech_st/10.1.2/opmn/bin/opmnctl start



$ kill -9 10879108 30867490 40960050






2. Now check the other window where the cloning process is running. It will start continue the cloning process.



Note : If the process still hangs, then check the opmn once again and kill it.


Reference :

R12 Cloning 'adcfgclone.pl appsTier' fails with error RC-50013: Fatal: Failed to instantiate driver .../regclone.drv [ID 725995.1]